VOELKEL VIETNAM
Hotline: 096 717 0718 Email: pkd@mike.vn 🇻🇳 🇬🇧
Voelkel
Dưỡng đo ren trong

Precision Dưỡng kiểm ren trong - NPT 1/8 x 27

★ 0.0 (0 đánh giá) • Đã bán 0
Lượt xem: 0
Precision Dưỡng kiểm ren trong - NPT 1/8 x 27 VÖLKEL, mã 16136, phù hợp cho kiểm tra độ chính xác của ren.
SKU: 16136
5.280.000 đ
Trạng thái kho: Hết hàng
Giá đã bao gồm VAT
Mô tả

VÖLKEL Precision Dưỡng kiểm ren trong – NPT 1/8 x 27

The VÖLKEL Precision Dưỡng kiểm ren trong is a combined GO and NO-GO plug gauge for NPT 1/8 x 27 female threads. It provides reliable thread verification in line with international standards.

The reference temperature for parts and gauges is 20° Celsius. On request, VÖLKEL will issue a factory calibration certificate (price on request). Calibration is performed in an independent measurement laboratory using IAC thread scanners to the applicable specifications and standards (DIN, ISO, ANSI). ➜ Watch the video: Plug gauge – application

Features & Benefits

  • Combined GO/NO-GO plug gauge
  • Accurate verification of NPT 1/8 x 27 female threads
  • Reference temperature: 20 °C
  • Calibration in an independent lab with IAC thread scanners
  • Factory calibration certificate available on request

Ứng dụng

Use the GO side to confirm dimensional conformity; the NO-GO side must not fully engage. This ensures fit and function per drawing and standard.

Step-by-Step Procedure

  1. Conditioning: Stabilize workpiece and gauge at 20 °C.
  2. Cleaning: Thoroughly clean ren trong and gauge.
  3. GO test: Start GO side straight and screw in by hand only.
  4. Evaluate GO: GO must seat within the permitted depth (per drawing/standard).
  5. NO-GO test: Start NO-GO by hand; it must not fully engage. Do not force.
  6. Documentation: Record result, date, operator, gauge ID and ambient temperature.

Technical Data

  • Product type Precision Dưỡng kiểm ren trong
  • Thread NPT 1/8 x 27 (female)
  • Design Combined: GO / NO-GO
  • Reference temperature 20 °C
  • Standards DIN, ISO, ANSI (per specimen specification)

Calibration

Calibration is performed in a measurement laboratory separate from VÖLKEL using IAC thread scannersfollowing the defined specifications and standards (DIN, ISO, ANSI) for the respective specimen. A factory calibration certificate can be issued upon request.

FAQ

Q1: What does GO and NO-GO mean?
A: GO verifies that the thread is within tolerance; NO-GO ensures the upper tolerance is not exceeded (must not fully engage).

Q2: Why 20 °C reference temperature?
A: Dimensions vary with temperature. 20 °C ensures comparable, standards-compliant results.

Q3: Can I use tools to drive the gauge?
A: số Always insert by hand to avoid damage and false results.

Q4: Both GO and NO-GO engage fully—what now?
A: The thread is oversize/out of tolerance. Quarantine the part and rework or recheck.

Q5: How often should I calibrate?
A: Typically annually or condition-based when deviations occur.

Q6: NPT vs. NPTF—what’s the difference?
A: NPT typically needs sealant; NPTF is a dryseal design and may seal without additional sealant. Follow drawing/standard.

Got questions about the plug gauge or need advice on inspection tools? Reach out via our biểu mẫu liên hệ.


Thuyết minh kỹ thuật
Loại renamerican tapered pipe thread, taper 1:16
Tiêu chuẩnANSI /ASME B 1.20.1
Kích thướcNPT 1/8 x 27
Mã hàng16136
Tiêu chuẩn dưỡngANSI /ASME B 1.20.1
Chuẩn renANSI B1.20.1
Tags / Từ khóa: 16136

Đánh giá sản phẩm

Dựa trên 0 đánh giá
0.0
Tổng quan
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Hãy là người đầu tiên đánh giá “Precision Dưỡng kiểm ren trong - NPT 1/8 x 27”

Vui lòng đăng nhập để gửi đánh giá.
Sản phẩm vừa xem
Chưa có
096 717 0718
Voelkel Vietnam
👉 KDT Vinhomes Grand Park, 512 Nguyễn Xiển, Phường Long Bình, Thành phố Hồ Chí Minh, Việt Nam
👉 S203 - Vinhome Grand Park - Q9 - Thủ Đức - Tp. Hồ Chí Minh - Việt Nam.